* update the PR commit message, there should be 15 files modified
* km_opt=5 fix is in the develop branch, merge
* registry package using fmoist_run variable
* perhaps remove fmoist_freq and just leave fmoist_dt
* In module_fr_fire_driver.F, there is a comment about “time – assume
dt does not change”. Is that true or does the FFM work also with time
varying dt?
* does the FFM work with restart?
*  The call to fire_driver_em() has now fire_ifun_end = 2, where it
used to be 3. According to the code comments in module_fr_fire_driver.F,
fire_ifun_end = 3 has to do with initialization of time step. Is that
skipped now or embedded within fire_ifun_end = 2?
* How are the fuel classes initialized for a real case? It seems that
the FM values are prescribed from the solution of the fuel moisture model?
Could you document/explain that?

Revision as of 06:05, 2 February 2020


  • update the PR commit message, there should be 15 files modified
  • km_opt=5 fix is in the develop branch, merge
  • registry package using fmoist_run variable
  • perhaps remove fmoist_freq and just leave fmoist_dt
  • In module_fr_fire_driver.F, there is a comment about “time – assume

dt does not change”. Is that true or does the FFM work also with time varying dt?

  • does the FFM work with restart?
  • The call to fire_driver_em() has now fire_ifun_end = 2, where it

used to be 3. According to the code comments in module_fr_fire_driver.F, fire_ifun_end = 3 has to do with initialization of time step. Is that skipped now or embedded within fire_ifun_end = 2?

  • How are the fuel classes initialized for a real case? It seems that

the FM values are prescribed from the solution of the fuel moisture model? Could you document/explain that?